+ High temperature (HT): up to 750°F (400°C)
- Ambient temperature:
+ Operating: -5°F to 140°F (-20° to 60°C)
+ Storage: -40°F to 150°F (-40° to 65°C) 0 to 98% relative humidity, noncondensing conditions
- Process pressure:
+ Standard: up to 1500 psia (100 bara)
+ High pressure to 5000 psig (345 barg)
- Response time is adjustable from 1 to 100 seconds
- Power supply options:
+ 12 to 36 VDC, 100 mA (add 20 mA per output up to 60 mA)
+ 100 to 240 VAC, 50/60 Hz, 25 watts
+ Active loop, loop powered with 4 to 20ma output
- 316 stainless steel construction (other materials available)
- Fluids measured: steam, gases and liquids
- Up to 72 inches (2 m) available;Pipe sizes from 0.5 to 8 inches (1.3 to 20.3 cm); See 240Sor next generation 240i
- Accuracy:
+ Mass flow: +/- 1% of reading (liquids); +/- 2% of reading (gas & steam)
+ Volumetric: +/- 1.2% of reading (liquids); +/- 1.5% of reading (gas & steam)
- Repeatability:
+ Mass flow rate: +/- 0.2% of ful scale
+ Volumetric flow rate: +/- 0.1% of scale
+ Temperature: +/- 0.2°F (+/- 0.1°C)
+ Pressure: +/- 0.05% of full scale
+ Density: +/- 0.1% of full scale
- Rangeability up to 30:1 (accuracy maintained across entire range)
- Process fluid temperature:
+ Standard: -40°F to 500°F (-40°C to 260°C)
- Output signals:
+ 3 programmable 4 to 20 mA
+ User definable pulse output for totalized flow
- Hazardous-Area Location Enclosure (IP66) and NEMA 4X (IP65)
- Digital communications: RS-485, Modbus RTU, HART (with DD), BACnet See next generation 241i.