| Technical Specification: | 
        
        
            | Ground Continuity | 
        
        
            | Display Range | 
            0.00Ω to 199Ω | 
        
        
            | Measuring Range | 
            0.01Ω to 199Ω | 
        
        
            | Accuracy | 
            2% + 5 digits | 
        
        
            | Resolution | 
            0.01Ω maximum | 
        
        
            | Open Circuit Test Voltage | 
            4VDC, nominal | 
        
        
            | Test leads zero | 
            Zero up to 10 Ω, by Zero button | 
        
        
            | Test Lead Compensation | 
            Null out up to 10Ω | 
        
        
            | Number of measurements | 
            5,000 1 second tests | 
        
        
            | Audible / visible warning | 
            ≥ 30VAC/DC at inputs | 
        
        
            | User Protection | 
            Warning and test inhibited if ≥ 30VAC/DC at inputs | 
        
        
            | Insulation Resistance (auto short circuit test) | 
        
        
            | Display Range | 
            0.1MΩ to 20MΩ | 
        
        
            | Measuring Range | 
            0.1MΩ to 20MΩ | 
        
        
            | Accuracy | 
            5% + 5 digits | 
        
        
            | Resolution | 
            0.1MΩ maximum | 
        
        
            | Open Circuit Test Voltage | 
            250V, 500V, 1000VDC (as per IEC 61557-2) | 
        
        
            | Test current | 
            1mA nominal as per IEC 1557-2 | 
        
        
            | Short circuit test current | 
            <2mA | 
        
        
            | Number of measurements | 
            5,000 1 second tests | 
        
        
            | Audible / visible warning | 
            ≥ 30VAC/DC at inputs | 
        
        
            | User protection | 
            Test inhibited if ≥ 30VAC/DC at inputs | 
        
        
            | Insulation resistance (point to point) | 
        
        
            | Display Range | 
            0.05MΩ to 300MΩ | 
        
        
            | Measurement range | 
            0.05MΩ to 300MΩ | 
        
        
            | Accuracy | 
            5% + 5 digits | 
        
        
            | Resolution | 
            0.01MΩ maximum | 
        
        
            | Open circuit test voltage | 
            250, 500, 1000V (as per IEC 61557-2) | 
        
        
            | Short circuit test current | 
            <1mA | 
        
        
            | Number of measurements | 
            5,000 1 second tests | 
        
        
            | Audible / visible warning | 
            ≥ 30VAC/DC at inputs | 
        
        
            | Circuitry protection | 
            Test inhibited if ≥ 30VAC/DC at inputs | 
        
        
            | Voltage measurement (via 4mm probes) | 
        
        
            | Display Range | 
            30V – 440VAC/DC | 
        
        
            | Measurement Range | 
            30V – 440VAC/DC | 
        
        
            | Resolution | 
            1V | 
        
        
            | Accuracy | 
            ±(5%+2d) | 
        
        
            | Vo/c voltage measurement (via PV test leads) | 
        
        
            | Display range | 
            0.0V – 1000VDC | 
        
        
            | Measurement range | 
            5.0V – 1000VDC | 
        
        
            | Resolution | 
            0.1V | 
        
        
            | Accuracy | 
            ±(0.5%+2d) | 
        
        
            | Enunciators | 
            DC voltage polarity correct or reversed | 
        
        
            | Is/c current measurement (via PV test leads) | 
        
        
            | Display range | 
            0.0A – 15.0ADC | 
        
        
            | Measurement ranges | 
            0.5A – 15.0ADC | 
        
        
            | Resolution | 
            0.1A | 
        
        
            | Accuracy | 
            ±(1%+2d) | 
        
        
            | Operating current (via DC current clamp) | 
        
        
            | Display range | 
            0.0A – 40.0A AC/DC | 
        
        
            | Measurement ranges | 
            0.1A – 40.0A AC/DC | 
        
        
            | Resolution | 
            0.1A | 
        
        
            | Accuracy | 
            ±(5% + 2 digits) | 
        
        
            | DC power | 
        
        
            | Display range | 
            0.0W – 40.0kW | 
        
        
            | Measurement ranges | 
            10W – 40.0kW | 
        
        
            | Resolution | 
            10W max | 
        
        
            | Accuracy | 
            ±(6% + 2 digits) | 
        
        
            | I-V curve | 
        
        
            | Voltage measurement range | 
            5.0V – 1000V | 
        
        
            | Voltage measurement accuracy | 
            ±(0.5%+2d) | 
        
        
            | Current measurement range | 
            0.5A – 15.0A | 
        
        
            | Current measurement accuracy | 
            1% | 
        
        
            | Power measurement range | 
            5W – 15kW | 
        
        
            | Power measurement accuracy | 
            2% |