AC withstand voltage test |
Rated output capacity |
200VA (5000V/40mA), short circuit current is greater than 200mA;
(Optional: 500VA (5000V/100mA), short-circuit current greater than 200mA;) |
Output voltage |
Range/accuracy |
100~5000V, ±(1%× setting +5V) |
Output frequency |
Range/accuracy |
50Hz or 60Hz, ±0.1%× setting |
Alarm current |
Upper limit/accuracy |
0.10~40.00mA, ±(1%× setting +5 words) |
Lower limit /accuracy |
0.000~9.999mA, ±(1%× setting +5 words) |
Time |
Range |
0.5~999.9s (0: infinite time) |
Ramp-up time |
0.1~999.9s (0: off) |
Ramp-down time |
0.1~999.9s (0: off) |
Accuracy |
± (0.2%× setting +1 word) |
Measure meter |
Voltage range/accuracy |
0.01~5.00kV, ± (1%× reading +2 words) |
Current range/accuracy |
0.10~40.00mA, ± (1%× reading +5 words) |
Time range/accuracy |
0.1~999.9s, ± (0.2%× reading +1 word) |
Output voltage wave, distortion, adjusting rate |
Sine wave, less than 2% (pure resistive load), ± (1% × setting + 5V) (from zero to full load) |
Start voltage |
(0%~50%)× output voltage setting |
Current compensation |
0.000~40.00mA, Auto/manual |
Arc detection |
Level 1~9, 9: highest level; 0: off |
DC withstand voltage test |
Output voltage |
Range/accuracy |
100~6000Vdc, ± (1%× setting +5V) |
Alarm current |
Upper limit/accuracy |
0~10000μA, ± (1%× setting +5 words) |
Lower limit /accuracy |
0.0~999.9μA, ± (1%× setting +5 words) |
Time |
Range |
0.5~999.9s(0: infinite time) |
Ramp-up time |
0, 0.4~999.9s (0: off) |
Ramp-down time |
0, 1.0~999.9s (0: off) |
Accuracy |
± (0.2%× setting +1 word) |
Measure meter |
Voltage range/accuracy |
0.01~6.00Vdc,±(1%×读数值+2个字)
0.01~6.00Vdc, ± (1%× reading +2 words) |
Current range/accuracy |
0.0~10000uA, ± (1%× reading +5 words) |
Time range/accuracy |
0.1~999.9s, ± (0.2%× reading +1 word) |
Rated output capacity |
60VA(6000Vdc/10mA) |
Output adjustment |
± (1%× setting +2V), zero to full load |
Compensation current |
0 ~200.0μA, Auto/manual |
Start voltage |
(0%~50%)×output voltage setting |
Charging current lower limit |
(0~3.500) μA, Auto/manual |
Discharge time |
≤200ms |
Arc detection |
Level 1~9, 9: highest level; 0: off |
Insulation resistance test |
Output voltage |
Range/accuracy |
100~2500Vdc, ± (1%× setting +5V) |
Alarm resistance |
Upper/lower limit |
0.1MΩ~999.99MΩ,1000MΩ~50000MΩ,上限包含无上限设定
0.1MΩ~999.99MΩ, 1000MΩ~50000MΩ, the upper limit includes no upper limit setting |
Accuracy |
100-499V, 0.10MΩ~999.99MΩ, 1000~2000MΩ, ± (5%× setting +2 words)
500-2500V, 0.10~999.99MΩ, ± (2%× setting +2 words),
1000~9999MΩ, ± (5%× setting +2 words)
10000~50000MΩ, ± (15%× setting +2 words) |
Time |
Ramp-up time |
0,0.1~999.9s (0: off) |
Delay decision time |
0, 0.5~999.9s (0: infinite) |
Range |
0, 0.5~999.9s (0: infinite) |
Ramp-down time |
0, 1.0~999.9s (0: off) |
Accuracy |
± (0.1%× setting +0.1s) |
Measure meter |
Voltage range/accuracy |
100~2500Vdc, ± (2%× reading +5 words) |
Resistance range/accuracy
|
Range: 0.100 MΩ~9.999 MΩ, 10.00 MΩ~99.99 MΩ, 100.0 MΩ~999.9 MΩ, 1.000 GΩ~50.00GΩ
Resolution: 0.001 MΩ, 0.01 MΩ, 0.1 MΩ, 0.001GΩ, 0.01GΩ
100-499V, 0.10~9.999MΩ, 10.00~99.99MΩ, 100.0~999.9MΩ, 1~2GΩ, ± (5%× reading +2 words)
500-2500V, 0.100~9.999MΩ, 10.00~99.99MΩ, 100.0~999.9MΩ, ± (2%× reading +2 words),
1.000~9.999GΩ, ± (5%× reading +2 words)
10.00~50.00GΩ, ± (15%× reading +2 words) |
Time range/accuracy |
0.1~999.9s, ± (0.2%× reading +1 word) |
Charging current lower limit |
0~3.500μA, Auto/manual |
Grounding resistance test |
Rated output |
Maximum output current: 32A; maximum test resistance: 600mΩ; maximum open circuit voltage: 12V |
Output current |
Range/accuracy |
2.0~32.0A, ± (1%× setting +2 words) |
Output voltage |
Range/accuracy |
3.0~6.4V , ± (1%× setting +2 words) |
Output frequency |
Range/accuracy |
Sine wave, 50Hz or 60Hz, ±0.1%× setting |
Alarm limit |
Resistance upper/lower limit |
Range: (0.1~600)mΩ (2.0~10.6)A;
(0.1~R)mΩ (10.7~32.0)A, R= (6400/current setting) mΩ. As the current scale is switched, the tester will automatically calculate the maximum scale.
Resolution: 0.1/1 mΩ |
Error |
± (1%× setting +2 words) |
Compensation resistance |
Range |
0~100 mΩ, automatic measurement , compensation On/Off |
Test time |
Range/accuracy |
0.5~999.9s (0: infinite); ± (0.2%× setting + 1 word) |
Measure meter |
Current range/accuracy |
2.0~32.0A( or 64A), ± (1%× reading +2 words) |
Voltage range/accuracy |
3.0~10.0V , ± (1%× reading +2 words) |
Resistance range/accuracy |
10.0~99.9~100~600mΩ;± (1%× reading +2 words)
|
Time range/accuracy |
0.5~999.9s (0: infinite); ± (0.2%× setting +1 word) |
Leakage current test |
Leak test body network (MD card) |
Standard network, GB/T 12113 Fig. 4; (Optional: other leak test network) |
Probe position |
Ground leakage current: G-L, G-N, AUTO (G-L, G-N); Surface leakage current: PH, PL |
Test power state |
Polarity switch: On/Off/Auto;
Ground switch: On/Off
Zero line connection switch: On/Off |
Test voltage output |
Single-phase, with external isolation transformer or variable frequency power supply to provide the required test voltage and frequency. |
Test voltage upper/lower limit |
Upper/lower limit Range: 0.0V~300.0V AC, Resolution: 0.1V, 45Hz~65Hz,
Error: ± (0.4%× setting +0.1%× scale) |
Test voltage measurement |
Range: 0.0V~300.0V, 45Hz~65Hz, Resolution: 0.1V, 45Hz~65Hz,
Accuracy: 20.0V~300.0V: ± (0.4%× reading +0.1%× scale) |
Load current |
20A |
Current upper/lower limit (RMS) |
Range: 0.0uA~999.9uA, 1000uA~9999uA, 10.00mA~12.00mA
Resolution: 0.1uA, 1uA, 0.01mA
Error:
0.0uA~999.9uA: DC: ± (1.5%× setting + 10 words)
15Hz≤f≤100kHz: ± (1.5%× setting + 10 words)
100kHz<f≤1000kHz, 10.0uA~999.9uA: ±5%× setting
1000uA~7999uA: DC: ± (1.5%× setting + 10 words)
15Hz≤f≤100kHz: ± (1.5%× setting + 10 words)
100kHz<f≤1000kHz, 10uA~7999uA: ±5%× setting
8.00mA~12.00mA: DC: ± (1.5%× setting + 10 words)
15Hz≤f<1000kHz, 0.01mA~12.00mA: ±5%× setting |
Current measurement (RMS) |
0.0uA~999.9uA: Resolution: 0.1uA
DC: ± (1.5%× reading + 10 words)
15Hz≤f≤100kHz: ± (1.5%× reading + 10 words)
100kHz<f≤1000kHz, 10.0uA~999.9uA: ±5%× reading
1000uA~7999uA: Resolution: 1uA
DC: ± (1.5%× reading + 10 words)
15Hz≤f≤100kHz: ± (1.5%× reading + 10 words)
100kHz<f≤1000kHz, 10uA~7999uA: ±5%× reading
8.00mA~12.00mA: Resolution: 0.01mA
DC: ± (1.5%× reading + 10 words)
15Hz≤f<1000kHz, 0.01mA~12.00mA: ±5%× reading |
Current compensation |
Range: 0.000 ~ 1.000mA, automatic measurement, On/Off. |
Test time |
Range: 0, (1 ~ 999.9), 0: infinite, Resolution: 0.1s, accuracy: ± (1% × setting +1 word). When the test mode is AUTO (G-L, G-N), the time is half. |