| Use power | DC110V ± 10% | 
        
            | Testable items | Minimum holding current of Toshiba, Hitachi, Meiden Fuji of electromagnetic holding type and scale test scale test of the Mitsubishi of machine-held
 | 
        
            | Electromagnetic hold graduation test circuit | Output voltage | DC5 ~ 115V (continuously variable) constant voltage control | 
        
            | Output current | 10A (more than the rated capacity constant current control) 10A (30 minute rating)
 | 
        
            | Electromagnetic-held holding current test circuit | Current measurement | 0 ~ 1A (continuously variable) constant current control as possible to adjust the fixed amount in accordance with the impedance of the * measured load, it is constant current control.
 | 
        
            | Machine-held HSCB scale test circuit | Output voltage | DC0 ~ 1.6V (continuously variable) constant voltage control | 
        
            | Output current | 10mA (continuous rating) | 
        
            | Electromagnetic hold graduation test ammeter | Measurement range | 0 ~ 10.00A (resolution 0.01A) 7-segment LED | 
        
            | Measurement accuracy | ± 0.5% rdg ± 5dgt | 
        
            | Sampling rate | 2.5 times / sec. | 
        
            | External current meter terminal | To the measurement section and the series of current meter, and providing an external current meter terminal. | 
        
            | Electromagnetic-held holding current meter | Measurement range | 0 ~ 1.000A (resolution 0.01A) 7-segment LED | 
        
            | Measurement accuracy | ± 0.5% rdg ± 5dgt | 
        
            | Sampling rate | 2.5 times / sec. | 
        
            | External current meter terminal | To the measurement section and the series of current meter, and providing an external current meter terminal. | 
        
            | Mechanical hold graduation test voltmeter | Measurement range | 0 ~ 1.999V (resolution 0.001V) 7 segment LCD | 
        
            | Measurement accuracy | ± 0.5% rdg ± 5dgt | 
        
            | Sampling rate | 2.5 times / sec. | 
        
            | External voltmeter terminal | To the measurement section and the series of voltage meter, provided the external voltage meter terminal. | 
        
            | External dimensions | 530 (W) × about 300 (D) × about 440 (H) | 
        
            | weight | 20kg | 
        
            | accessories | Power cord, (for external current meter) short bar, manual |