Use power |
DC110V ± 20% |
Voltage output |
DC25 ~ 75V (continuously variable) |
Output current |
17A (0.2 seconds) 1A (Continuous) |
Output control |
In "ON" switch, and output between the input -N.
In "OFF" switch, output between switching -N. |
Output voltage meter |
|
199.9V (resolution 0.1V) 7-segment LED |
Measurement accuracy |
± 0.5% rdg ± 5dgt |
Sampling rate |
2.5 times / sec. |
Contact measurement function |
Measurements CH |
6CH |
Measurement time |
0 ~ 50/100/250 / 500ms ( resolution 0.1Ms)
0 ~ 5000 / 20000Ms (resolution 2ms) |
measurement error |
0.01% rdg ± 0.3ms (resolution 0.1Ms)
0.01 Pasento rdg ± 0.6Ms (resolution 2ms) |
Detecting circuit |
Contact input detection voltage DC24V measure current up to 30mA |
Record start condition |
Start a measurement when you press the "ON" or "OFF" of the voltage output operation |
Contact status display function |
When the measured contact of the closed circuit condition, the lamp is lit |
Noise mask function |
ON within measurement contact 3ms, when you repeat the OFF state, it does not record a change in the state of contact is regarded as noise. |
CO characteristic function |
Operation |
"ON" in the state press the switch to "ON" by pressing the switch input voltage is output (measurement start), after the set time has elapsed from the time of any of the main contact is operated (on state), and outputs a switching voltage.
* Measurement operation of the measuring time does not change anything. |
Set time |
Measurement time 50 ~ 500ms range, 1 ~ 99ms (1ms unit)
measurement time 5000 ~ 20000ms range, 10 ~ 990Ms
(10Ms units) |
Current measurement function |
Measurement range |
0 ~ 20A (resolution 0.1A) |
measurement error |
± 1% rdg ± 2dgt |
display |
40-digit two-line LCD display |
Print out output |
Built-in printer (paper width 80 mm) |
External dimensions |
250 (D) × 480 (W) × 360 (H) |
weight |
About 10.7kg |