- Built-in battery system in the 0 ~ 60kV to output , extra-high voltage for the pressure test, it can insulation diagnostic test , power supply, built-in battery, external AC100V, is 3 power system of external DC24V.
- The power supply unit, integrated measurement unit, lightweight design in the compact.
Thông số kỹ thuật
Use power |
Built-in power supply DC24V
external power supply DC24V
power capacity 10A or more (that the power of the output terminal is not grounded)
external power supply and charging AC100V (50 / 60Hz) |
Internal battery |
Lead-acid battery (DC12V, 2 this 7Ah) |
Power consumption |
Up to 500W |
Output voltage meter |
DC60kV 1.0 grade with mirror |
Output ammeter |
10Myuei / 100Myuei / 1MA / 10MA / SHORT
5-stage switching 1.0 grade with mirror |
Current Symbol green meter output |
1μA in DC10mV |
Output accuracy |
Within ± 2% ※ that the input impedance of the recorder is 1MΩ or more |
Voltage recorder output |
1kV in DC10mV |
Output accuracy |
Within ± 5% ※ that the input impedance of the recorder is 1MΩ or more |
Output voltage |
DC0 ~ 60kV (negative polarity) |
Output current |
2.5mA (short-circuit), 600μA (when -60k occurs) |
Ripple |
Within ± 1% of the output voltage value (-5 ~ -60kV) |
Load variation rate |
Within ± 1% for the FS -60kV (connecting the rated load than the no-load) |
External dimensions |
247 (D) × 435 (W) × 440 (H) |
weight |
About 26kg |
accessories |
Test code set (with storage bag) and discharging resistance bar owner manual case cover |