Model |
XP-3118 |
Gas Detected |
Combustible gases and vapors
(specify gas detected) |
Oxygen |
Detection Principle |
Catalytic combustion |
Galvanic cell |
Sampling Method |
Extractive |
Detection Range |
0 to 100 %LEL |
0 to 25.0 vol% |
Indication Accuracy
(Under identical
conditions) |
±5% of full scale |
±0.3vol%
(Compliant with JIS T 8201) |
Alarm Set Value |
25%LEL |
18.0vol% |
Display |
LCD digital (with backlight)
Digital display
Digital bar display |
Alarm Indication |
Gas alarm: Intermittent buzzer, Red lamp flashing
Error alarm: Buzzer, Red lamp flashing, LCD display |
Explosion-Proof
Structure |
Ex ib d IIC T3 (TIIS)
II 2 G Ex dib IIB Td Gb (ATEX)
Ex dib IIB T4 Gb (IECEx)
Class I, Zone 1, AEx d ib IIB T4 Hazardous Locations. (UL) |
Operation
Temperature |
0 to +40 °C |
Power Source |
4 x AA alkaline dry battery |
Battery Life*1 |
Up to 20 hours |
Dimensions |
W82 x H162 x D36 mm |
Weight |
Approx. 450g (16oz.) (excluding batteries) |
Standard
Accessories |
Soft case, 4 x AA alkaline dry battery, Gas sampling hose (1meter),
Probe with filter/moisture trap
|
Optional
Accessories |
2-30 meter gas sampling hose, Gas dilution probe,
Data download software (CD-ROM software and USB cable)
|