Measurement Kit:
|
Including:
ASV5910+-2 noise dosimeter*5
AWA6022A sound calibrator Type 2 *1
Microphone adaptor (from ½” to ¼”)*1
|
ASV5910+-2 Noise Dosimeter Specifications
|
Applied Standards:
|
IEC 61252:2002 Personal Sound Exposure Meters,
IEC61672-2002,Class 2;
ANSI S1.25:1991 Personal Noise Dosimeters
|
Microphone:
|
1/4 inch prepolarized condenser field replaceable threaded microphone
|
Measurement Range:
|
40-140dBA,70-143dBC(sensitivity: -53 dB )
|
Peak C Measuring Range:
|
70 to 143dB
|
Frequency Range:
|
20Hz to 12.5kHz
|
Frequency Weightings:
|
Parallel (simultaneous) A, C, Z
|
Time Weightings:
|
Parallel (simultaneous) F, S, I, Peak
|
Selectable thresholds :
|
40 to 90dB
|
Exchange rates:
|
3, 4, 5 and 6
|
Selectable criterion:
|
70 to 90dB
|
Dose exposure measurement range:
|
0.01Pa2h ~ 99.99Pa²h
|
Noise dose measuring range:
|
0% ~ 9999%
|
Integrating time:
|
1 second ~ 24 hours
|
Memory capacity:
|
32GB TF card
|
Sampling interval of statistic analysis:
|
0.01s
|
Calibration information:
|
Calibration dates, times, and levels
|
Internal software function:
|
Integrating Function, Statistical Analysis Function
|
Security:
|
Lock via keys
|
Power supply:
|
Rechargeable lithium polymer battery
|
Battery life:
|
36 hours run capacity
|
Dimensions:
|
68(H)×68(W)×20(D)mm
|
Weight:
|
85g
|