| Measuring range 1)                                                                    GUM–53_–01–_ GUM–53_–02–_
 GUM–53_–06–_
 GUM–53_–10–_
 GUM–53_–20–_
 | 0.1 ... 1 m0.2 ... 2 m
 0.2 ... 6 m
 0.4 ... 10 m
 0.5 ... 20 m
 | 
        
            | Supply voltage                                                                     GUM–53N–_ _–_ | 18 ... 36 V DC | 
        
            | Current supply                                                                       GUM–53N–_ _ –I GUM–53N–_ _ –U
 GUM–53N–_ _ –M
 | 4 ... 20 mA / max. 22 mAMax. 12 mA
 Max. 20 mA
 | 
        
            | Current output                                                                       GUM–53_–_ _ –I Voltage output                                                                      GUM–53N–_ _ –U
 Modbus output                                                                      GUM–53N–_ _ –M
 | 4 ... 20 mA (limit values 3.9 ... 20.5 mA)0 ... 10 V (limit values 0 ... 10.2 V)
 Modbus RTU protocol
 | 
        
            | Resolution | < 1 mm | 
        
            | Accuracy(within the total range) GUM–53_–01 in area 0,1–0,2 m / 0,2–1,0 m
 GUM–53_–02; –06
 GUM–53_–10; –20
 | 0,3 % / 0,2 %0,15 %
 0,2 %
 | 
        
            | Temperature error | Max. 0,04% / K | 
        
            |   Beamwidth (-3 dB)                                  GUM–53_–01–_ ; 02–_ ; 10–_GUM–53_–06–_
                                                          GUM–53_–20–_    | 10°14°
 12°
 | 
        
            |   Ambient temperature range      GUM–53_–01–_ ; 02–_ ; 06–_                                                          GUM–53_–10–_ ; 20–_ | -30 ... +70°C-30 ... +60°C
 | 
        
            |   Measuring period                                    GUM–53_–01–_; 02–_                                                          GUM–53_–06–_; 10–_                                                                                            GUM–53_–20-_                                                          GUM–53_–_ _–M               | 0,5 s1,2 s
 5,0 s
 adjustable via Modbus RTU
 | 
        
            |   Averaging (can be modified according to agreement)                                                           GUM–53_ – _ _–_GUM–53_–_ _–M
 | 4 measurementadjustable via Modbus RTU
 | 
        
            | Short time temperature stress resistance | +90°C / 1 hod. | 
        
            | Max. operation overpressure (on transmission surface) | 0,1 MPa | 
        
        
        
            | Failure indication echo failure – basic mode
 echo failure – inverse mode
 level in dead zone – basic mode
 level in dead zone – inverse mode
 |   3,75 mA (0 V)22 mA (10,5 V)
 22 mA (10,5 V)
 3,75 mA (0 V)
 | 
        
            | Protection class | IP67 | 
        
            | Recommended cable | PVC 2 x 0,75 mm2 (3 x 0,5 mm2) | 
        
            | Maximal current output load resistance       at U = 24 V DC at U = 22 V DC
 at U = 20 V DC
 | Rmax = 270 ΩRmax =180 Ω
 Rmax = 90 Ω
 | 
        
            | Minimal voltage output load resistance | Rmin > 1 kΩ | 
        
            | Delay between supply power rise time and first measurement GUM–53_–01–_ ; 02–_ ; 06–_
 GUM–53_–10–_; 20–_
 |   5 s9 s
 | 
        
            | Process connection GUM–53_–01–_
 GUM–53_–02–_
 GUM–53_–06–_
 GUM–53_–10–_
 GUM–53_–20–_
 |   thread G ¾‘‘thread G 1‘‘
 thread G 1½‘‘
 thread G 2¼‘‘
 aluminium alloy flange
 | 
        
            |   WeightGUM–53_–01–_
                                                                          GUM–53_–02–_GUM–53_–06–_
 GUM–53_–10–_
 GUM–53_–20–_
 | 0,20 kg0,20 kg
 0,25 kg
 0,65 kg
 2,80 kg
 |