|                                                                              GUM–70_–02   Measuring range 1)                                         GUM–70_–06GUM–70_–10
 GUM–70_–20
 | 0.15 ... 2 m0.25 ... 6 m
 0.4 ... 10 m
 0.5 ... 20 m
 | 
        
            | Adjustable measuring range (SPAN) | Min. 200 mm | 
        
            | Supply voltage                                                GUM–70_– _ _ | 18 ... 36 V DC | 
        
            | Output                                                              GUM–70_–_ _–_–I GUM–70_–_ _–_–M
 | 4 ... 20 mA (Limit values 3.9 ... 20.5 mA), HART®RS-485 with protocol Modbus RTU
 | 
        
            | Current consumption                                    GUM–70_–_ _-_-I GUM–70_–_ _-_-M
 | 4 ... 20 mA / Max. 22 mAMax. 20 mA
 | 
        
            | Resolution                                                       GUM–70_–02 ; 10 GUM–70_–06
 GUM–70_–20
 | < 1 mm< 2 mm
 < 2,5 mm
 | 
        
            | Accuracy (within the total range) | 0,15 % | 
        
            | Temperature error | Max. 0,04% / K | 
        
            | Operating frequency                                    GUM–70_–02 GUM–70_–06
 GUM–70_–10
 GUM–70_–20
 | 120 kHz75 kHz
 50 kHz
 30 kHz
 | 
        
            | Beamwidth (-3 dB)                                        GUM–70_–02 ; 10 GUM–70_–06
 GUM–70_–20
 | 10°14°
 12°
 | 
        
            | Ambient temperature range                       GUM–70_–02 ; 06 GUM–70_–10 ; 20
 | -30 ... +70°C-30 ... +60°C
 | 
        
            | Short-time temperature stress resistance | +90°C / 1 hod. | 
        
            | Max. operation overpressure (on transmission surface) | 0,1 MPa | 
        
            | Sensitivity | 3 stupně (low – medium – high) | 
        
            | Damping | 0 ... 99 s | 
        
            | Measuring period | 1 ... 4 s | 
        
            | Rise time | cca. 30 s | 
        
            | Additional technical data for Ex proof – Max. internal values | Ui=30V DC; Ii=132mA; Pi=0,99W; Ci=370nF; Li=0,9mH | 
        
            | Failure indication (echo loss, level in dead zone 3), internal failure)
 | Adjustable in modes:3.75 mA ; 22 mA ; Last measured value
 | 
        
            | Protection class |  IP67 | 
        
            | Mechanical connection                                GUM–70_–02 GUM–70_–06
 GUM–70_–10
 GUM–70_–20
 | Screwing with thread G 1''Screwing with thread G 1½''
 Screwing with thread G 2¼''
 Aluminium alloy flange
 | 
        
            | Recommended cable                                    GUM–70_–_ _–_–I GUM–70_–_ _–_–M
 | PVC 2 x 0,75 mm2PVC 2 x 2 x 0,25 mm2 (twisted pair, shielded)
 | 
        
            | Maximal resistance of current output load U = 24 V DC U = 22 V DC
 U = 20 V DC
 | Rmax = 270 Ω 2)Rmax = 180 Ω
 Rmax = 90 Ω
 | 
        
            | Weight                                                              GUM–70_–02 GUM–70_–06
 GUM–70_–10
 GUM–70_–20
 | 0.3 kg0.4 kg
 0.7 kg
 3.1 kg
 |