Supply voltage GDM – 35_–_ _–_–I
GDM – 35_–_ _–_–U
|
9 ... 34 V DC
12 ... 34 V DC
|
Current output
Voltage output |
4 ... 20 mA (2-wire)
0 ... 10 V (3-wire)
|
Power consumption GDM–35_–_ _–_–I
GDM–35_–_ _–_–U |
3,75 ... 20.5 mA
5 mA (voltage output open circuit)
|
Non-linearity |
max. 1 %
|
Temperature error |
max. 0.05% / K
|
Voltage error for current and voltage output |
max. 0,3 μA/V and 0,1 mV/V
|
Leakage resistance electrode - housing / dialectic strength |
1 MΩ / 200 V DC
|
Coupling capacity (housing - power) / dielectric strength |
50 nF / 500 V AC
|
Coupling capacity (electrode - power) / dielectric strength |
47 nF / 500 V AC
|
Ambient temperature range: |
- 40 ... + 85 °C
|
Protection type GDM-35_-_ _-C-_-_
type GDM-35_-_ _-A(B,V,H)-_-_ |
IP67
IP68
|
Maximum load resistance for current output (at U = 24 V) |
Rmax= 700 Ω
|
Weight (excluding electrode and cable) performance N
performance NT |
approx. 0.3 kg
approx. 0.6 kg
|
Cable (version with cable glands) |
PVC 2 x 0.75 mm2 or 3 x 0.5 mm2 (according to design)
|