Differential Pressure |
Resolution |
0.1 Pa |
Display Range |
±999.9Pa、(Accuracy guaranteed range±1000Pa) |
Accuracy |
±2.5% of rdg ±1Pa、50Pa or lower±2Pa |
Sensor Proof Pressure |
5 MPa |
Dislay Unit |
Test Pressure |
kPa,MPa
(Non SI Unit for overseas use kg/cm2, PSI, bar, mmHg,他)
|
Leak Rate |
Pa, kPa, mL/s, mL/min, L/min, Pa・m3/s,
E-3 Pa・m3/s, Pa/s, Pa/min,*Pa/s, *Pa/min
(Non SI Unit for overseas use mmH2O, mmHg, inH2O,Others) |
K(Ve)
(Leak Coefficient) |
mL, L (Non SI Unit for overseas use in3, ft3) |
Leak Rate Display |
4 digits, Sampling Rate 10 times/sec |
Leak Limit |
999.99 max |
Number of Channels |
32ch(0~31) |
Timer |
999.9 sec(Resolution 0.1 sec) |
Power Source |
AC100~240V±10%, 50/60Hz,70VA max |
Ambient Temperature |
5~45 ℃ |
Humidity |
80% RH or less / No dew condensation |
Weight |
Controller: approx. 2.6kg, Pneumatic unit: approx. 7.1kg |
Test Pressure Source |
Clean and dry air regulated to the test presssure
Source pressure must be sufficiently higher than the test pressure |
Pilot Pressure |
Set by using the pilot pressure filter regulator installed: Range: 400 to 700kPa |
Port Size |
M1K1 |
Special joint is used only for WORK and MASTER port tubing |
M3K4 |
Rc(PT)1/4: Pressure source, WORK and MASTER ports) |
CPU |
SH-2A 144MHz, DRAM8MB |
RS-232C
(D-sub 9pin) |
ID2 Format |
Limit values as well as Large leak limit and Small leak limit are transmitted |
L2 Format |
LL-DET and S-DET test results are transmitted |
Others |
Other 4 formats available |
USB Port |
Test data |
Judgment, Leak, Test pressure, Channel #, Time, etc |
Test parameter |
Test parameters of all the settings screens |
Standard Accessories |
Pilot pressure filter regulator,Quick mounting brackets,Control I/O connector, Power cord, Inspection recordsOperation manual(CD),Traceability documents |