Model |
LZ-3000
|
Target workpieces |
Small, sealed electronic components
|
Processing capabilities |
Maximum of 60 pieces/minute (1.0 second/piece)
|
Gross leak test system |
Micro-volume detection type air leak tester system
|
Number of air leak testers included: |
8
|
Air leak tester specifications |
Model |
LUV-880-KX03
|
LUV-880-KX05
|
LUV-880-KX2
|
Minimum workpiece internal clearance volume |
0.3 mm^3 or more
|
0.5 mm^3 or more
|
2.0 mm^3 or more
|
Minimum detectable equivalent price standard leak amount |
1.17×10^-6 Pa・m^3/sec
|
5×10^-6 Pa・m^3/sec
|
2×10^-5 Pa・m^3/sec
|
Target workpiece size |
2.0×1.6 2.5×2.0mm
|
2.5×2.0 3.0×3.0 3.2×2.5mm
|
3.8×3.8 5.0×3.2 9.5×7.2mm
|
Workpiece supply method |
Lined-up supply from part feeder with hopper
|
Workpiece transport system |
Movable pick and place, left to right two-part index
|
Inspection movements |
Full-automatic operation |
■ Normal operation, ■ Calibrating operation, ■ Recovery operation
|
Manual operation |
■ Individual operation, ■ Calibrating operation, ■ Return to original position, ■ Withdrawing operation
|
Decision processing |
Collection of sorted out defective pieces in collection bucket
|
Self-diagnosis function |
Self-diagnosis of tester malfunction, individual movement malfunction, pressure anomaly, etc.
|
Information output |
Automatic collection of measurement result data on USB memory, RS-232C
|
Environment conditions |
5~40℃
|
Power Source |
Three-phase 380V and three-phase 200V, 50/60Hz 1.5kW
|
Air pressure source |
0.4MPa or greater 250L/min pipe size: Rc1/2 (PT1/2 internal thread)
|
Outer dimensions |
1250 (W)×1450(Max1890)(H)×850(D) mm
|
Options |
* Compatible with similar workpieces of multiple types
* Workpiece supply discharge (online compatible/ career magazine compatible)
|
Documents |
Traceability documents, Operation manual
|